Enter one or more keywords to search.
Wildcards - "*" and "?" are supported.
Search results for: Restoration-Bond
Results per page:
Category:
4 results found
https://completemarkets.com/Article/article-post/367/Getting-Personal-Ivan%E2%80%99s-Heart/
...of my grandchildren and my auto restoration hobby. Quite frequently those pict...
https://completemarkets.com/Article/article-post/62/25-Marketing-Ideas-You%E2%80%99ve-Probably-Never-Considered-Using-Before/
...motions can help create a powerful bond with potential clients and existing f...
https://completemarkets.com/Article/article-post/1025/HOW-TO-AVOID-THE-12-MOST-COMMON-CAUSES-OF-BROADCAST-TOWER-LOSS/
.... Utilize an Emergency Restoration Service (ERS). Provide for an...
https://completemarkets.com/company/CompleteMarkets/Articles/content-package/IMMS-Library/TabCategory/article-post/1025/HOW-TO-AVOID-THE-12-MOST-COMMON-CAUSES-OF-BROADCAST-TOWER-LOSS/
... include guy wire retensioning and tower bolt tightening. This type of preventive maintenance not only solves problems but also may help to identify potential causes of damage. 8. LOSS CONTROL PROCEDURES. An absence of some or all key loss control procedures can result in an unnecessary signal loss. Taking the right steps in advance will help keep the station on the air and minimize down time. Utilize an Emergency Restoration Service (ERS) . Provide for an auxiliary tower. Provide for a back-up antenna. Provide for an alternative source of power: 1) install an on-site generator; 2) contract for emergency generator use; or 3) use a grid review to obtain power from another direction. Have a reciprocal arrangement to share towers with another station. 9. LEASING TOO MUCH TOWER SPACE. With ... possibility of lightning losses. Here is a checklist to help minimize tower damage by lightning. Lightning rods should project well above the tower beacon. Use binoculars to verify that the rods are in place and in good condition since severe lightning hits may vaporize them. Guy wire anchor points should be grounded to the nearest radial by copper strap. For grounded towers, at least four 10-foot rods must be bonded to the tower base and in contact with the groundwater table. Soil must be tested to determine conductivity. For insulated towers, the ball gap should be clear of debris so that the bare metal is exposed. Insulated towers should have a static drain choke connected between the feedline and the station ground. Insulated towers should have two 12-foot loops in the feedline between the tower and the transmitter housing ...